BRAND GLASS PARAFLAM EI-60
In accordance with the Federal Law No. 123-ФЗ "Technical Regulations on Fire Safety Requirements",
fire-resistant glass Brand Glass Paraflam EIW-60 is intended for use in fire-resistant translucent
structures of exterior and interior use (windows, doors) in buildings with fire resistance of buildings
and structures and fire bays of type I. EIW-60 glass is used in fire-prevention doors of the first type
of fire resistance with glazing over 25%.
Paraflam EIW-60 manufactured according to TU 5924-001-79710207-14 and complies with the requirements of GOST 30826-2014 "Laminated glass". PARAFLAM fire-resistant glass meets the fire-insulation and fire-resistance criteria in compliance with the technical standard EN 1363-1.
Glass maximum size 1550 x 3200.
Paraflam belongs to the class of safety glasses.
Glass does not requires special protection from moisture.
The glass is resistant to ultraviolet radiation, including hard UV-C.
Warranty period - 5 years, service life not less than 25 years
Resistance to fire (ГОСТ 33000-2014, EN 13501-2) | EI60 |
Reaction to fire (EN 13501-1) | A 1 |
Thickness [mm] (tolerance ±2) | 24 |
Weight of square meter [kg/m²] | 44 |
Light transmittance factor τv (ГОСТ-EN 410 2014) [%] | 87.1 |
Light reflectance factor ρv (ГОСТ-EN 410 2014) [%] | 7.8 |
Solar direct transmission factor τe (ГОСТ-EN 410 2014) [%] | 63.7 |
Solar direct reflectance factor ρe (ГОСТ-EN 410 2014) [%] | 6.8 |
Total solar energy transmittance factor g (ГОСТ-EN 410 2014) [%] | 70.6 |
Sound reduction (ГОСТ-EN 12758 2015) Tw (C; Ctr): [dB] | 42 |
Pendulum body impact resistance (ГОСТ-EN 12600 2015,) | 1/B/1 (СМ4) |
Thermal properties (ГОСТ-EN 673 2015): U-Value [W/(m².K)] | 5.8 |
Operating temperature [ºС] | -30 .. +50 |
Durability test (EN 12543-part 4) | PASS |